Galvanized PC strand

Galvanized PC Strand is a high-strength steel cable made of multiple high-carbon steel wires twisted together, coated with a protective zinc layer. The galvanization enhances corrosion resistance, making it ideal for prestressed concrete structures, bridges, and infrastructure exposed to harsh environments.

Key words: Galvanized PC strand

DESCRIPTION

Galvanized PC Strand is applied to stay cables, main cables and anchoring systems of bridge cable structures, external cables of arch bridge slings and other pre-stressed structures that do not directly contact with concrete mortar.

The diameter of our product is 12.70mm, 15.20mm, 15.70mm, 17.8mm and it is low relaxation pre-stressed strand.

The coated steel wire is further drew and stabilized by heat treatment, then intermediately made to galvanized strand. The strand has no binding, and won't get loose after cutting. The surface coating is uniform and continuous, and the straightness is good. The mechanical properties meet the requirements of ASTMA416, prEN10138, NFA35-035 and other international standards.

The strand has a uniform lay length, which is 12-16 times of the nominal diameter. The coating mass of the single wire is 190~350g/m2. The aluminum content of the zinc-aluminum alloy steel strand coating is not less than 4.2%. The coating adhesion is strong, and the coating is uniform without leakage. The amount of zinc can meet the requirements of A475-09, level A. 

It combines durability, tensile strength, and long-term performance.

Key parameter:

Nominal Diametermm Tensile Strength Rm/Mpa Specifications Minimum difference between center wire and outer wires   mm       
Max. Force KN≥ 0.2% Proof Force KN≥ Elongation under Max. Force % 1000h Relaxation(Initial Load 0.7)  r / % Deflective Tensile Coefficient % Pulsating Tensile Fatigue
Inhaul Cable Non Inhaul Cable Inhaul Cable Non Inhaul Cable
12.7 1770 175 156 ≥3.5 ≤2.5 ≤20 ≤28 Stress Limit 0.45 FmStress Amplitude 300MPa

2.0×106 times

No breaking
Stress Limit 0.7 FmStress Amplitude 190MPa

 2.0×106 times

No breaking
0.08
1860 184 164
1960 194 173
15.2 1770 248 221 ≥3.5 ≤2.5 ≤20 ≤28 0.11
1860 260 232
1960 274 244
15.7 1770 266 237 ≥3.5 ≤2.5 ≤20 ≤28 0.12
1860 279 249
1960 294 262
17.8 1770 338 301 ≥3.5 ≤2.5 ≤20 ≤28 0.15
1860 355 316
1960 374 333

Packing and Loading:

  