DESCRIPTION
Unbonded PC Strand is a prestressed steel cable coated with a corrosion-resistant layer (e.g., grease or wax) and encased in a protective plastic sheathing. Unlike bonded strands, it remains isolated from surrounding concrete, allowing free movement during tensioning. Widely used in post-tensioned concrete structures for enhanced flexibility, durability, and resistance to environmental stress.
The specifications is conforming with JG 161-2004. Steel is in accordance with GB/T5224-2014, or EN10138/BS5896,or ASTM A416, or other standards clients require. Sheathing: GB 11116,GB/T9341. Grease: JG3007-1993.
Tensile Strength:1670Mpa, 1700Mpa, 1770Mpa, 1820Mpa and 1860Mpa etc.
Diameter: 9.50mm-17.80mm
Structure: Commonly 1x7 wire.
Application:
PC steel strands unbonded are mainly used for prestressed steel structure and construction of cable-stayed bridges.
Advantages: Its application in recoverable anchor cables saves a lot of cost for engineering projects.
Common Specifications
| Standard | Unbonded pc strand | Weight of oil (g/m) Not less than |
Thickness of PE (mm) Not less than |
Friction factor u |
Coefficient of effect on friction(K) | ||
| Nominal diameter (mm) |
Area of section (mm) |
Tensile strength (MPa) |
|||||
| JG161-2004 | 9.5 | 54.8 | 1720 | 32 | 0.8 | 0.04-0.10 | 0.003-0.004 |
| 1860 | |||||||
| 1960 | |||||||
| 12.7 | 98.7 | 1720 | 43 | 1 | 0.04-0.10 | 0.003-0.004 | |
| 1860 | |||||||
| 1960 | |||||||
| 15.24 | 140 | 1570 | 50 | 1 | 0.04-0.10 | 0.003-0.004 | |
| 1670 | |||||||
| 1720 | |||||||
| 1860 | |||||||
| 1960 | |||||||
| 15.7 | 150 | 1770 | 53 | 1 | 0.04-0.10 | 0.003-0.004 | |
| 1860 | |||||||